Backflow is the undesirable reversal in the flow of water from a real or potential source of contamination back to the potable (or clean) water supply. Consider having a garden hose in a bucket of soapy water at your home, and having backflow event occur causing that soapy water to "backflow" into the drinking water portion of your home. Various types of backflow preventers exist for different applications and health hazard conditions, check state and other local administrative codes or other regulation on the correct backflow to use. The most common are reduced pressure backflow preventer and double backflow preventer valves. Backflow preventers are primarily used in sewer, wastewater, residential, sprinkler and irrigation backflow applications.

Backflow Prevention Devices

The term "Cross-Connection Control" is essentially is referring to backflow prevention. The definition of a Cross Connection is "A cross connection is the actual or potential connection between a non-potable substance or source." Local authorities will dictate what types of backflow preventers may not be used depending on the backflow risk and health hazard. Sewer, irrigation, wastewater and residential are the main areas. There are two types of backflow, the first is back pressure where the pressure in the downstream piping is greater than the supply pressure, this is caused by a pump or elevation of water in a high rise building, the other type of backflow is back siphonage which is caused by sub-atmospheric pressure in the water system piping.

Glen-Flo manufactures:

  • Backflow Preventers
  • Backflow Prevention Devices  
  • Double Backflow Prevention Valves  
  • Wastewater Backflow Prevention Devices
  • Residential Backflow Prevention Devices

See below for more Backflow Preventer Valve variations


Test Kits
backflow preventers Test Kit TK 1
This backflow prevention assembly test kit is designed for field testing of all brands of reduced pressure principle, double check and pressure vacuum breakers.
View Details
Submit RFQ

Atmospheric Vacuum Breaker
backflow preventer valves GFAVB
Atmosperic Vacuum Breaker
Size(s): 1/2 to 2 in. (15 to 50 mm)
View Details
Submit RFQ
Dual Check Valve
GF8080S6

GF8080S6

Dual Check Valve

Size(s): 3/4  & 1 in. (20 & 25 mm)

View Details
Submit RFQ

Hose Connection Vacuum Breaker
backflow prevention GFB8
Hose Connection Vacuum Breakers
Size(s): 3/4 in. (20 mm)
View Details
Submit RFQ

Dual Check Valve
backflow preventers GF8080E
Dual Check Valve
Size(s): 1/2 to 1 in. (15 to 25 mm)
View Details
Submit RFQ

Dual Check Valve w/ Atmos. Vent
backflow prevention GF8200
Dual Check Valve with Atmospheric Vent
Size(s): 1/2 to 3/4 in. (15 to 20 mm)
View Details
Submit RFQ

Backflow Prevention Devices | Wastewater | Residential

Various types of backflow preventers exist for different applications and health hazard conditions, check state and other local administrative codes or other regulation on the correct backflow to use. The following backflow preventer types are available in all sizes:

Dual Check Valve - Model GF8080, GF8080E - The Dual Check Valve or double backflow prevention valve is basically a stripped down Double Check Valve without shut off valves and test cocks. They are non-testable and are typically used by water companies and installed after a water meter to prevent the meter from running backwards and low protection against backflow. This piece of equipment is the center of controversy with many backflow authorities and should never be confused with Double Check Valves. Check with local authorities for required installation, as most do not recognize these as backflow prevention devices.

Atmospheric Vacuum Breaker - Model GFAVB - The atmospheric vacuum breaker is one of the least expensive backflow prevention assembly. The GFAVB is a non-testable unit and are good for back siphonage only for non-health hazard or health hazard conditions. They must be installed downstream from any shut off valves and cannot be under pressure for more than 12 hours. If an GFAVB is used backflow prevention on a irrigation system you must install one GFAVB after every valve for each zone in the system. It must also be installed at least 6 inches (150 mm) higher than the highest outlet in the system (some GFAVB manufacturers, and some local officials, require that they be installed 12 inches (300 mm) higher than the highest outlet). Some municipalities do not allow the use of GFAVB’s. These units will NOT prevent backflow pressure and can only protect against back siphonage.